Once the required output torque has been determinate, the gearbox may be selected from the data sheet.
The output torque for motorized operation should also be used in case of extreme environmental conditions or when a high safety factor is required. The output torque for manual operation can be used for rare motorized applications or when lower safety factors are acceptable. In this case however, the stall torque of the actuator must not exceed double the input torque. Please contact our office, if you are in doubt.| Description | M | Gearbox size, e.g.M05, M07, M40, MF40 MW... - Gearbox for 180°-360°degrres M...SD - gearbox with declutch for manual override driven actuators. |
| F | F = Gearboxes for motorization with input adapter for electrical or hydraulic actuator. |
| DB9/IS3,5 |
DB9 Spur gear. D9 = ratio 9:1 D12 = ratio 12:1 DB6 = ratio 6:1 DB9 = ratio 9:1 DB12 = ratio 12:1 IS3,5 = ratio 3,5:1 Combinations of two sizes DB spur gears are possible. |
| GO/F10 |
GO Input adapter
F10 = DIN 3210 G0 |
| PF | Padlocking flange |
| CI | Cast iron indicator |
| RI | Raised indicator |
| SP | Special paint |
| R 18 |
Size of hand wheel
R = Steel welded, black painted. |
|
Specification |
Environmental Requirement |
|
SL020 |
Low temperature (-60°C/+60°C), not shock proof, material GGG. |
|
SL021 |
High temperature (+25°C/+200°C) |
|
SL024 |
Sulphuric acid |
|
SL025 |
Acetylene |
|
SL026 |
Ammonia |
|
SL027 |
Chlorine |
|
SL029 |
Oxygen |
|
SL035 |
British Gas V6 |
|
SL039 |
Waterproof (-40°C/+80°C) |
|
SL040 |
Marine/Tropics |
|
SL041 |
Admiralty |
|
SL042 |
Admiralty (low magnetic conductivity) |
|
SL048 |
Stainless steel valve operators |
|
SL050 |
Submarine and tank installation (crude oil/sea water down to 25 m depth) |
|
SL052 |
Submarine and tank installation (mixed and refined products down to 25 m depth) |
|
SL060 |
Fire save |
|
SL070 |
Buried service (dry) |
|
SL072 |
Buried service (wet) |
|
SL075 |
Desert |
|
SL080 |
AWWA * (Weatherproof) |
|
SL081 |
AWWA Dry chamber |
|
SL082 |
AWWA Buried Service Compressed Soil |
|
SL083 |
AWWA Wet chamber |
|
SL084 |
AWWA Submersible |
|
SL099 |
Exhibition |
|
SL120 |
Low temperature (-60°C/+60°C), shock proof, material LCC. |
|
SL129 |
Oxygen gas phase environment |
|
SL139 |
Protection class IP67 |
|
SL150 |
Submersible (deep sea below 25m) |
![]() |
![]() |
![]() |
| Waterproof - specification SLO39 | Marinised - specification SLO40 | Marine submersible - specifications SLO50, SLO52, SLO53. |
![]() |
![]() |
![]() |
| Buried service - specification SLO70 | Buried service - Specification SLO71 | Buried service-Specification SLO72 |